@@ -128,6 +128,14 @@ My mounting holes are causing the footprint to get errors on Validation
|
||||
Add the designators associated with the mounting hole pads
|
||||
Uncheck all the boxes regarding what is visible
|
||||
Click OK
|
||||
|
||||
|
||||
My mounting holes are causing the footprint to get errors on the Design Rule check "Hole Size Constraint"
|
||||
|
||||
Open Constraint MNAGER
|
||||
Tab "All Rules"
|
||||
Scroll to Manufacturing > Hole Size
|
||||
Increase the Maximum to your hole size or create a new rule for your mounting holes specifically
|
||||
|
||||
What if my component's pins have a missing number in the sequence? Validation fails!
|
||||
|
||||
|
||||
@@ -0,0 +1,5 @@
|
||||
# Bookmarks for later use
|
||||
* [Defining, Scoping & Managing PCB Design Rules: creating a new rule](https://www.altium.com/documentation/altium-designer/pcb/defining-scoping-managing-design-rules#creating-a-new-rule)
|
||||
* [Defining Design Requirements Using the Constraint Manager](https://www.altium.com/documentation/altium-designer/sch-pcb/constraint-manager)
|
||||
* [Processes and Workflows](https://www.altium.com/documentation/altium-365/processes-workflows)
|
||||
* [Altium 365 Workspace Quickstart(https://my.altium.com/altium-365/getting-started/what-is-a365-workspace)
|
||||